BroadVibra Software Update History

Version 2.8.5

  • Add OTA ability for SVT-V and SVT200-T series wireless sensors with minimum power consumption increase. Requires SVT-V or SVT-T sensor firmware v2.9 or higher
  • Add MQTT remote control feature for wireless IMU SAG200

Version 2.8.4

  • Add velocity RMS to trend analysis in the software. Change acceleration RMS name from “RMS” to “Acceleration RMS”
  • Increase history data review plot resolution for SVT-T series wireless temperature sensors

Version 2.8.3

Version 2.8.2

  • Add Hanning window for FFT analysis for better spectrum leakage handing in the vibration analysis
  • Add MQTT message output for SAG200 wireless IMU
  • Fix a bug that when user refreshes new timer setup page, the display shows previous setup instead of the current one
  • Fix a bug that when user sets up a new timer, the timer needs to be turned on once to see available groups.

Version 2.8.1

  • Added gateway clock display, so that when there is discrepancy between gateway clock and local computer time, the gateway clock should be adjusted accordingly. Sensor data are saved to the database, and queried using gateway clock, so that it is important to have correct gateway clock.
  • Update trend analysis MQTT message format, add sensor description and gateway name to trend analysis message. This allows unlimited amount of sensors for a user.
  • In timer setup, change minimum DAQ period from 5 minutes to 3 minutes, which allows for more frequent data acquisition
  • Use the latest data for trend analysis, instead of using the earliest data from user-selected time. This ensures to update the trend if user takes large amount of data in the analysis interval.
  • Fix a bug that sensor info table is not updated when importing sensor config file since version 2.8.0

Version 2.8.0

  • Added SAG200 wireless IMU sensor support
  • Simplified timer setup. Make it easy to set up periodic DAQ for multiple groups
  • Fixed sensor information update time bug at the end of each month
  • Auto clear alarms every 2 hours, so that users do not need to reset the alarms manually.

Version 2.7.9

Version 2.7.8

  • Added MQTT remote gateway software update feature
  • Added MQTT remote DAQ SVT-A trigger mode support
Version 2.7.7
  • Added the feature of SVT-V sensor triggered SVT-A sensor group scan. When an SVT-V sensor’s velocity or acceleration RMS level exceeds  alarm threshold, an SVT-A sensor group can be selected to take data in predefined DAQ mode.
Version 2.7.6
  • Added machine RPM (optional) for SVT-A series wireless vibration sensor
  • Added RPM 1x, 2x, … for FFT analysis
  • When add a SVT-A sensor group, zone mapping is created automatically
  • Timer zone/group mapping is displayed at the timer page
  • Added MQTT control remote alarm clear ability

Version 2.7.5

  • Added client id support for external MQTT broker.
  • Simplified wireless gateway configuration export. One click to download current gateway and sensor configuration with gateway name
  • Added sample rate fine tuning for each SVT-A series wireless vibration sensor for very accurate frequency analysis purpose
  • Added peak-peak parameter for trend analysis
  • FFT plot added peak bands and peak values for x, y, z axes
  • Change default SVT-A series wireless vibration sensor trigger threshold from 0.1g to 0.5g
  • Fixed daylight-saving bug (when querying database with “start date and time”, there could be time shift due to daylight saving)
  • MQTT remote FFT message added peak-peak measurements of the waveform

Attention: Upgrading to this version and above may need to update the gateway’s internal dashboard node. New dashboard node improves on history data query by date time zone issue. Please refer to the BroadVibra software update guide for details on how to update the node.

Version 2.7.4

  • Added single JSON mode that sends out single DAQ and trigger mode data in JSON string at the end of DAQ
  • MQTT vibration trend analysis message added group number
  • In FFT vibration analysis and history data review, added trigger mode display (undefined before)
  • Optimized FFT export CSV file (use DAQ start time, removed data arrival time to avoid confusion), added DAQ information to header
  • Fixed the bug that database reset may not be complete when there is database operation in progress. This bug causes data saving issue to the database.

Version 2.7.3

  • Optimized periodic DAQ with timers. Periodic DAQ allows multiple timers from different groups/zones to overlap each other. Added “apply changes” button to start periodic DAQ immediately with new DAQ period and duration.

Version 2.7.2

Version 2.7.1

  • When a sensor is not connected to the gateway for 1 day, “sensor last update” info will become orange color; if not connected for 2 days, it will become red color
  • Fix single FFT bug when there are multiple sensors, the sensor ID only shows the same id and same temperature. The bug was introduced at version 2.5.5

Version 2.7.0

  • Allow to have multiple groups of SVT-V series wireless vibration & temperature sensors. This increases the number of SVT-V sensors supported in a gateway dramatically
  • Change “zone/group” wording to “group/zone”. This makes it easier to select a group among dozens of gateways in the same factory
  • Added new SVT200-T wireless temperature sensor support. Allows multiple groups of SVT-T sensors
  • Fixed a bug that the external MQTT broker control may not work for certain MQTT brokers.
  • Removed “reset” button on “sensor info” table. Added the ability to hide individual information table

Version 2.6.9

  • Added the feature to reset the database to factory default. This allows to quickly clean all data.
  • Allow user to type in values for alarm setup besides using cursors
  • If “save to database” switch is turned off, then SVT-V series wireless vibration & temperature sensors data won’t be saved

Version 2.6.8

  • Separated sensor information and sensor data in MQTT output. User can select and send out only sensor info now
  • When a sensor is not added in the wireless gateway, then the sensor data and info will not be sent out with MQTT from the gateway
  • Added remote MQTT sensor list feature to obtain complete sensor information
  • In single DAQ mode, if a sensor is not added in the gateway, but the sensor is in the same group as other sensors in the gateway, then there will be “Invalid sensor” message to remind user to change the sensor’s group.

Version 2.6.7

  • Added step forward and step backward button for FFT vibration analysis, which makes it easy to change data set
  • Added step forward and step backward button for history data review
  • Added waiting message information during history data review & FFT analysis

Version 2.6.4-2.6.6

  • Added gateway info, vibration trend analysis, alarm, topic to external MQTT broker
  • Added remote MQTT FFT analysis support. User can fetch time domain data and its FFT analysis via MQTT. The data is in JSON string format for easy parsing
  • Added switch to turn on/off MQTT gateway information

Version 2.6.2-2.6.3

  • Added external MQTT broker TLS support (on/off)
  • In history data review, added individual selection of SVT-V sensors.

Version 2.6.1

  • Added MQTT reset function. The gateway can be remotely reset with MQTT command
  • Added external MQTT broker setup in the front panel. When external MQTT broker is used, internal MQTT broker will be disabled

Version 2.6.0

  • Added vibration velocity calculation at FFT analysis page
  • Automatically calculates acceleration offset at SVT-V series wireless vibration & temperature sensors. No need to manually adjusts now
  • Changed SVT-V sensor velocity output to velocity RMS output. Added ISO 10816 reference table for easy comparison

Version 2.5.9

  • In FFT analysis, added RMS calculation at time waveform display

Version 2.5.8

  • Added support for SVT300-V and SVT400-V real-time wireless vibration & temperature sensors
  • Removed edge effect when filtering is enabled at FFT analysis
  • At FFT analysis, if filter is enabled, then the time-domain data output is filtered data, instead of raw data

Version 2.5.7

  • Added the feature that when restarting gateway, the BLE chip resets automatically

Version 2.5.3-2.5.6

  • Improved history data review for SVT-A series wireless vibration and temperature sensors. Removed “playback” selection. Automatically calculates elapsed time with sample rate.
  • FFT analysis x-axis changed to time (seconds). In the time domain data display, it shows data acquisition mode and sampling rate information.
  • Gateway firmware version shows more detail (one more digit)
  • Fixed a bug of vibration trend analysis file data index not-aligned well with values

Version 2.5.2

  • Fixed a bug that in single FFT mode, only the last sensor data is sent to MQTT
  • Added temperature MQTT upload in single FFT mode

Version 2.5.0

  • Added Live FFT and single FFT data acquisition modes in the front page of the vibration analysis software
  • Added automatic FFT result transfer of single FFT result to remote servers using MQTT protocol

Version 2.4.0-2.4.1

  • Removed synchronization number entry. Gateway automatically calculates synchronization numbers
  • Improved live data display by upgrading the plotting plug in.
  • Reduced data saving volume to micro SD to prolong its life

Version 2.3.5

  • Optimized sensor info table date & time display
  • Added color display for battery level
  • Added screen auto scale ability for small screens

Version 2.3.1

  • Improved SMTP email setup compatibility with certain email servers

Version 2.3.0

  • Added Imperial unit option
  • Added sensor configuration export and import function
  • Added gateway chipset information

Version 2.2.0-2.2.2

  • Added sync-Multi DAQ mode
  • Added periodic DAQ function to the timer
  • Added gateway location information (latitude & longitude)
  • Send gateway information in one MQTT message now (more efficient)

Version 2.1.9:

  • Added wireless gateway firmware version
  • Automatic update sensor list in the DAQ interface when sensor is adjusted
  • Always show Alarm email setup information now
  • Updated gateway MQTT info, added “up time”.
  • Make SVT-V sensors velocity and acceleration display color consistent

Version 2.1.8:

  • Fix wireless gateway GU200 occasional manual start fail issue. Need gateway firmware version 2.2 and above

Version 2.1.7:

  • Added multi DAQ function. Continuous run of single DAQs
  • Removed 100ms rest time for batch mode. Allows more data to be acquired and transferred at batch mode.

Version 2.1.6:

  • Added automatic single DAQ turn off function when number of finished sensors reach the total sensors in the group.
  • After switching zone, first-time DAQ curve does not flash to give user better experience.

Version 2.1.5:

  • Automatically adjust zone order after user enters a new zone

Version 2.1.4:

  • Fixed an acceleration range bug that is introduced at version 2.1.0 (individual setup adjustment was not applied to range in certain cases)
  • Disable range adjustment during single DAQ

Version 2.1.3:

  • Added software update ability in the dashboard (easier to update software)
  • Added hover color effect for all buttons

Version 2.1.2:

  • Added MQTT remote control ability

Version 2.1.1:

  • Improved alarm info. Now email shows detailed alarm information
  • Optimized sensor configuration. Added “cancel” buttons;
  • Added SVT-V series wireless vibration & temperature sensor current group number display
  • Removed sensor No. Only use sensor ID from now on. It is easier to input sensor info
  • Improved sensor info table display speed. Automatically adjust sensor orders

Version 2.1.0:

  • Added individual group/zone sampling rate, range and mode adjustment ability
  • Increased automatic timer clock accuracy from 60s to 1s

Version 2.0.9:

  • Added single sensor selection for data review and increased data download limit to 160,000
  • Added gateway MQTT alarm output and vibration trend analysis output options
  • Improved sensor adjustment and added auto detection of duplicate sensor id entered by a user

Version 2.0.8:

  • Added emailing alarm function to dashboard

Version 2.0.7:

Version 2.0.6:

  • Always use Eth0 for the MAC address now. Also show both Ethernet and WiFi IP
  • Updated SVT200-A voltage display to show correct voltage level

Version 2.0.5:

  • Sensor firmware 2.1 fixed SVT200-A wireless vibration and temperature sensor current leak introduced from firmware v2.0
  • Added highlighted power switch. Makes it look nicer
  • Added highpass, lowpass filter options for FFT analysis

Version 2.0:

  • Added adjustable sampling points function for single DAQ mode.
  • Maximum number of single DAQ points increased to 16384
  • Added Kurtois, skewness and crest factor for trend analysis
  • Added group/zone mapping, plus group/zone delete function
  • Added sensor delete function
  • Added alarm set up for different group/zones
  • Added alarm for SVT200-V sensor

Version 1.8:

  • Added the option of 100Hz and 200Hz sampling rate at real-time mode.
  • Improved batch-mode transmission speed.
  • Slightly improved single DAQ speed by ~10%.

Version 1.7:

  • Add single DAQ mode and synchronized single DAQ mode (true sampling rate guaranteed at the sensor side).
  • JavaScript timing library accuracy increased from milli seconds to microseconds

Version 1.6:

Version 1.1-1.5:

  • Added true vibration sampling rate option (batch mode) for FFT vibration analysis. In batch mode, true sampling rate is ensured at each batch.
  • Added synchronized sampling option. All devices in the same group are synchronized to start DAQ in milliseconds level.
  • Added FFT analysis ability in the gateway.
  • Added sensor information in the gateway, including serial number, MAC address, RSSI & battery power.

Version 1.0: Initial release